Deskripsi
Konektor Andrew 1/2 Inch N-Male Type : L4PNM
Andrew L4PNM type N-Male Connector L4PNM-H Type N Male for 1/ 2 in LDF4-50A cable Manufactured by Andrews as their part number L4PNM-RC these are a top quality stainless steel ring flare type 50 Ohm N type male connector.
General Specifications:
- Interface : N Male
- Body Style : Straight
- Brand : HELIAX® | RingFlare™
- Mounting Angle : Straight Electrical
Specifications:
- Connector Impedance : 50 ohm
- Operating Frequency Band : 0 – 8800 MHz
- Cable Impedance : 50 ohm
- 3rd Order IMD, typical : -120 dBm @ 910 MHz
- 3rd Order IMD Test Method : Two + 43 dBm carriers
- RF Operating Voltage, maximum ( vrms) : 707.00 V
- dc Test Voltage : 2000 V
- Outer Contact Resistance, maximum : 0.30 mOhm
- Inner Contact Resistance, maximum : 2.00 mOhm
- Insulation Resistance, minimum : 5000 MOhm
- Average Power : 0.6 kW @ 900 MHz
- Peak Power, maximum : 10.00 kW
- Insertion Loss, typical : 0.05 dB
- Shielding Effectiveness : -130 dB
Mechanical Specifications:
- Outer Contact Attachment Method : Ring-flare
- Inner Contact Attachment Method : Captivated
- Outer Contact Plating : Trimetal
- Inner Contact Plating : Gold
- Attachment Durability : 25 cycles
- Interface Durability : 500 cycles
- Interface Durability Method : IEC 61169-16: 9.5
- Connector Retention Tensile Force : 890 N | 200 lbf
- Connector Retention Torque : 5.42 N-m | 48.00 in lb
- Insertion Force : 66.72 N | 15.00 lbf
- Insertion Force Method : MIL-C-39012C-3.12, 4.6.9
- Pressurizable : No
- Coupling Nut Proof Torque : 19.91 N-m | 176.25 in lb
- Coupling Nut Retention Force : 444.82 N | 100.00 lbf
- Coupling Nut Retention Force Method : MIL-C-39012C-3.25, 4.6.22
Dimensions:
- Nominal Size : 1/ 2 in
- Diameter : 22.00 mm | 0.87 in
- Length : 76.00 mm | 2.99 in
- Weight : 242.00 g | 0.53 lb
Environmental Specifications:
- Operating Temperature : -55 ° C to + 150 ° C ( -67 ° F to + 302 ° F)
- Storage Temperature : -55 ° C to + 85 ° C ( -67 ° F to + 185 ° F)
- Immersion Depth : 1 m
- Immersion Test Mating : Mated
- Immersion Test Method : IEC 60529: 2001, IP68
- Water Jetting Test Mating : Mated
- Water Jetting Test Method : IEC 60529: 2001, IP66
- Moisture Resistance Test Method : MIL-STD-202F, Method 106F
- Mechanical Shock Test Method : MIL-STD-202, Method 213, Test Condition I
- Thermal Shock Test Method : MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 ° C
- Vibration Test Method : MIL-STD-202F, Method 204D, Test Condition B
- Corrosion Test Method : MIL-STD-1344A, Method 1001.1, Test Condition A
Ulasan